Installation Instructions
• Turn off the water at the main.
• Cut the plaster shield so that it extends 3/8" above the surface of
the finished floor.
• Use an 8 mm allen wrench (not included) to remove the three
screws from the flush housing. Remove the flush housing. Do not
discard the screws.
• Use the reserved screws to attach the trim to the rough. Pivot the
top of the trim so that the spout faces the correct direction. Use
a level to make sure that the unit is straight.
• Seal the floor around the plaster shield with a waterproof,